U-Twin 한국어 Open the demo

U-Twin · Facility operations and maintenance

Where the problem is, and what it was like then.
A digital twin on the floor plan, honestly.

It gathers values from scattered business systems and equipment screens into each asset's place on the floor plan and shows them as one digital twin, designed to show where and when each value came from. What it does not know, it marks as unknown; what it has filled in, it marks as filled in.

On the customer's server · installed on a closed networkBusiness records stay in their original systemsPeople make the decisions
Garam Office Building, 3rd-floor operating twin On a tilted floor slab of the 3rd-floor plan, six assets stand as light pillars, and values flow in from equipment, metering and business sources. Air handler AHU-3 shows a supply air temperature of 23.4 degrees, its operating state is estimated, and its filter differential pressure has been disconnected since 13:52. Fan coil FCU-302 shows a value 21 minutes stale, the source corrected the 12:20 value for distribution board DP-3A, and the quality of elevator EV-2 is unknown. The band below is today's reconstructable range; 07:00–07:30 and 10:00–10:40 cannot be reconstructed. Garam Office Building · 3F Operating twin · floor plan rev. △4 · effective 2026-09-01 Values with indicators4/ 8Disconnected sources1GW-2Reconstructable today91.7% Now14:10 Office 301 Room A Mechanical room Office 302 Electrical room Lounge Elevator BMS-1Equipment · BMS EMS-1Metering · EMS CMMS-1Business · CMMS Disconnected since 13:52 GW-2Gateway 1 Q? FCU-30122.8°C FCU-A23.1°C AHU-3 air handlerMechanical room Supply air23.4°CEMS-1 · observed 14:10:04 Operating stateRunEst.BMS-1 · observation time unknown Filter diff. pressure182PaOffline · 13:52GW-2 · last value 13:40 EV-2 elevatorNormalUnknown · Q? FCU-302 fan coil24.0°CStale 21 minBMS-1 · observed 13:49 DP-3A distribution board38.7kW1CorrectedEMS-1 · source revised the 12:20 value 1F 2F 3F 4F Floors · 4 / viewing 3F Reconstructable range · today Unreconstructable · buffer lost Unreconstructable · host down 06:00 12:00 14:10 now

One twin, ten views.

The same assets, the same values and the same indicators are designed to be shown on the screen that fits the job. Stack the floors, put two points in time side by side, follow a power system, and open it on a phone in the field.

Garam Office Building floor stackA whole-building view with four floors stacked at an angle. On 3F there are four indicators and a disconnected gateway, on 4F one quality-unknown, on 1F one estimated. The cards on the right show asset counts, indicator counts and today's indicator trend per floor. Garam Office Building · Whole buildingFloors 4 · Assets 30 · Floor plan rev. △4Now14:10Reconstructable today91.7%Disconnected sources13F GW-2Values with indicators6/ 301F2F1Q?3FQ?4F4F · Rooftop machineryChiller · cooling tower9Assets1IndicatorsUnknown · tower flowIndicators · today3F · OfficeHVAC · distribution8Assets4IndicatorsOffline · GW-2 · since 13:52Indicators · todayGap2F · OfficeHVAC · lighting7Assets0IndicatorsNoneIndicators · today1F · Lobby · Fire control roomAccess · fire safety · elevators6Assets1IndicatorsEst. · elevator run timesIndicators · todayUpper floors in front · core columns between floors · open 3F for the operating twin board

Floor stack

Whole building · 2.5D

It is designed to show the whole building on one sheet by stacking the floors at an angle, and to set the values carrying indicators and the disconnected sources for each floor right beside it.

Every value carries its source and time.

A screen filled in smoothly is hard to trust. U-Twin is designed to leave normal values quiet and attach an indicator only to the others, like a legend on a drawing. The indicators follow wherever the value goes — screen, answer, export, replay — and cannot be turned off.

Legend · Honest displayLEGEND 1/1
23.4°C

Normal

No indicator. The source and time appear when you press the value.

Stale 21 min

Stale

The source observed that value longer ago than the threshold. A past value that arrived late falls here too.

Offline · 13:52

Down

There is no new observation. The last value and its time stay visible and are not erased.

Quality unknownQuality bad

Quality

The quality of the value as the source reported it. Uncertain and bad are shown as they are, and if none was reported it is 'unknown' — it is not filled in on the assumption that it is good.

Est.

Est.

A value that fills something empty. The original value (for example, unknown observation time) stays as it is, and the filled-in value is kept separately.

Calculated

Calculated

Calculated from the original values. The formula and inputs go along with it.

Unreconstructable · collection stopped

Gap

There is no basis to bring that span back. A gap is shown as a gap, with the reason written.

Corrected

Corrected

The source corrected the value for the same moment afterwards. The earlier value is not erased either.

The past as the source tells it now is shown as restatement, kept distinct from the record we received then.

History replay

Reopen 3F as of last Tuesday 10:00.

It is designed to rewind the layout, relationships and values to that moment. It shows the spans that can be restored and those that cannot together, and if you want, lays an estimate over the gaps.

  • Asset information whose past is not kept at the source is recorded directly each time it changes.
  • Choose between 'the past as known now' and 'what was shown on screen then'.
  • Even after the floor plan is revised, you view the old layout on the old drawing again.
Collection
NormalResent · normalNormal
Replay (default)
RestoredRestoredRestored
Estimate view
00:0004:0008:0012:0014:10
10:20Unreconstructable · host not responding10:00 ~ 10:40

Ask and answer

Answers carry evidence and time.

The AI is designed to assemble answers only from the values and history the twin has. It includes only numbers that are in the evidence or calculated from it, and states the range when an unobserved span is involved.

  • It echoes back the period it read 'last week' as.
  • Even without the AI, the same screen does the same job.
  • It uses the AI endpoint the customer chooses. It can be configured so that nothing leaves the site.
Was there a power outage on 3F last week?
In the observed range, there is no outage record for the 3F distribution boards.
GapTue 10:00 ~ 10:40 cannot be verified because collection was cut off.
Period 10/27 00:00 ~ 11/03 00:00EMS · DP-3A power · range queryCoverage · 2 gaps
What was AHU-3's average supply air temperature last week?
Average 23.1°C Calculated
Average (supply air temperature, 10/27–11/02)9,412 inputs · by observation

Back to work

Make the request right where you saw it. People make the decisions.

It is designed so that a work request created from an asset is recorded in the original business system. Each write states its effect beforehand, sends exactly what was confirmed, and is reflected on screen only after the business system replies that it received it.

  • Read Record — no write exists without a declared effect.
  • The AI goes only as far as a draft. The confirmation cannot be skipped.
Confirm work requestRecord
Target
CMMS · Work request
Assets
AHU-3 air handler · Mechanical room
Details
Filter differential pressure sensor not responding (since 13:52) — on-site check
Draft
AI draft · confirmation needed
Conf. no.
a3f9·27c1
Draft→Confirm→Send→System confirms
Send with this contentEdit

On the customer's server, with the customer's data.

U-Twin is designed to be installed in the customer's environment. The originals of business records stay in their original systems, and the twin holds only observed facts and layout.

Closed network

It comes in as an offline installation bundle and sends no usage statistics outside. Product status leaves only as a report the customer exports themselves.

The original stays where it is

The originals of work orders and the asset register stay in the business system. The twin records the values it read and their source.

Connect through adapters

One adapter per business system and equipment system connects them in a standard format. Adapters are left open so customers and partners can write their own.

Browser Twin ServerHonesty rules · history · permissions · audit Adapter hostCollection · write · disk queue Business system Equipment system HTTP JSONMutual authenticationRead

It is also clear about what it does not do.

Clear boundaries are what let you trust it enough to connect it.

It is not a control systemIt does not take on interlocks, real-time guarantees or safety certification. The last line of defense is the target system's permission check.
It does not replace business recordsIt does not hold or edit the originals of work orders or the asset register.
It does not act on its ownIt has no automatic agent that executes actions without a person's instruction.

Take a look first with a synthetic floor plan.

A demo made from one floor of a fictional office building, with no real customer data.